Split hydro box R410A, 1-phase, 12 kW

R410A split hydro box heat pump for heating, 12 kW, single-phase

HN1616M NK5 + HU121MA U33

  • Designed for buildings with high heating demand, delivering stable and reliable operation even in extreme climate conditions
  • The integrated hydronic module within the indoor unit reduces installation complexity and enhances overall system reliability
  • Flexible refrigerant piping options allow easier installation and better adaptability to different layouts and project requirements
  • High energy efficiency in line with ErP standards, achieving A+++ at 35°C and A++ at 55°C operating temperatures
  • Capable of producing hot water up to 57°C while maintaining efficient performance in outdoor temperatures as low as -25°C
  • Equipped with Wi-Fi control via LG ThinQ, with support for smart grid integration, photovoltaic (PV) systems, and energy storage solutions (ESS)

TECHNICAL SPECIFICATIONS

POWER SUPPLY
Voltage, phase, frequency (V, ph, Hz)220-240 V, 1 ph, 50 Hz
SEASONAL EFFICIENCY DATA (HEATING)
Seasonal space heating eff. class (35°C / 55°C)A+++ / A++
Seasonal space heating efficiency (ηS) (35°C / 55°C)183 / 131
SCOP (35°C / 55°C)4,65 / 3,36
NOMINAL CAPACITY AND COP (A+7/W+35)
Heating capacity (kW)12,00
COP4,55
NOMINAL CAPACITY AND COP (A+2/W+35)
Heating capacity (kW)11,00
COP3,62
NOMINAL CAPACITY AND COP (A+7/W+55)
Heating capacity (kW)11,00
COP2,55
NOMINAL CAPACITY AND EER (A+35/W+18)
Cooling capacity (kW)10,40
EER4,00
NOMINAL CAPACITY AND EER (A+35/W+7)
Cooling capacity (kW)7,94
EER2,98
OPERATION RANGE (OUTDOOR AIR TEMPERATURE)
Heating & DHW (min. ∼ max.), °C-25 ∼ 35
Cooling (min. ∼ max.), °C5 ∼ 48
OPERATION RANGE (LEAVING WATER TEMPERATURE)
Heating (min. ∼ max.), °C15 ∼ 57
Cooling (min. ∼ max.), °C5 ∼ 27
DHW (min. ∼ max.), °C15 ∼ 80
REFRIGERANT
TypeR410A
GWP2,088
Precharged amount (g)2,500
PIPING CONNECTIONS (OUTDOOR UNIT/REFRIGERANT CIRCUIT)
Gas (mm (inch))Ø 15,88 (5/8)
Liquid (mm (inch))Ø 9,52 (3/8)
Length standard / max. (m)7,5 / 30
Level difference max. (m)30
Max. length without additional charge (m)7,5
Additional refrigerant charge (g/m)40
PIPING CONNECTIONS (WATER CIRCUIT/INDOOR UNIT)
Inlet diameter for space heating (inch)Male PT 1″
Outlet diameter for space heating (inch)Male PT 1″
SOUND POWER LEVEL (OUTDOOR UNIT)
Rated / low noise mode (dB(A))63 / 61
SOUND POWER LEVEL (INDOOR UNIT)
Rated (dB(A))44
SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL)
Rated / low noise mode (dB(A))41 / 39
SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL)
Rated (dB(A))36
DIMENSIONS
Outdoor unit (WхHхD), (mm)950 х 1,380 х 330
Indoor unit (WхHхD), (mm)490 х 850 х 315
WEIGHT
Outdoor unit (empty), (kg)84,8
Indoor unit (empty), (kg)40,5
EXTERIOR
Outdoor unit (color / RAL code)Warm gray / RAL 7044
Indoor unit (color / RAL code)Noble white / RAL 9016