HN1600MC NK1 + HU121MRB U30
- Eliminates risk of refrigerant leakage inside the building, as the full refrigerant circuit is contained in the outdoor unit, ensuring higher safety and reliability
- Simplified installation without refrigerant piping and brazed connections, reducing setup time and potential errors
- Improved environmental performance and safety due to the closed refrigerant system and reduced exposure during installation and servicing
- Integrated hydraulic module in the indoor unit ensures stable operation of pump, sensors and control components
- Compact design simplifies connection, reduces installation complexity and makes maintenance easier
- High energy efficiency class ErP LWT A+++/A++ (35°C/55°C) ensures low energy consumption and efficient operation in low- and medium-temperature heating systems
TECHNICAL SPECIFICATIONS
| POWER SUPPLY | |
|---|---|
| Voltage, phase, frequency (V, ph, Hz) | 220-240 V, 1 ph, 50 Hz |
| SEASONAL EFFICIENCY DATA (HEATING) | |
| Seasonal space heating eff. class (35°C / 55°C) | A+++ / A++ |
| Seasonal space heating efficiency (ηS) (35°C / 55°C) | 181 / 137 |
| SCOP (35°C / 55°C) | 4,60 / 3,50 |
| NOMINAL CAPACITY AND COP (A+7/W+35) | |
| Heating capacity (kW) | 12,00 |
| COP | 5,04 |
| NOMINAL CAPACITY AND COP (A+2/W+35) | |
| Heating capacity (kW) | 11,00 |
| COP | 3,65 |
| NOMINAL CAPACITY AND COP (A+7/W+55) | |
| Heating capacity (kW) | 11,00 |
| COP | 2,90 |
| NOMINAL CAPACITY AND EER (A+35/W+18) | |
| Cooling capacity (kW) | 12,00 |
| EER | 4,75 |
| NOMINAL CAPACITY AND EER (A+35/W+7) | |
| Cooling capacity (kW) | 12,00 |
| EER | 2,70 |
| OPERATION RANGE (OUTDOOR AIR TEMPERATURE) | |
| Heating & DHW (min. ∼ max.), °C | -25 ∼ 35 |
| Cooling (min. ∼ max.), °C | 5 ∼ 48 |
| OPERATION RANGE (LEAVING WATER TEMPERATURE) | |
| Heating (min. ∼ max.), °C | 15 ∼ 65 |
| Cooling (min. ∼ max.), °C | 5 ∼ 27 |
| DHW (min. ∼ max.), °C | 15 ∼ 80 |
| REFRIGERANT | |
| Type | R32 |
| GWP | 675 |
| Precharged amount (g) | 2,100 |
| PIPING CONNECTIONS (WATER CIRCUIT/OUTDOOR UNIT) | |
| Inlet diameter (inch) | Male PT 1″ |
| Outlet diameter (inch) | Male PT 1″ |
| PIPING CONNECTIONS (WATER CIRCUIT/INDOOR UNIT) | |
| Inlet/outlet diameter for ODU connection (inch) | Male PT 1″ |
| Inlet/outlet diameter for space heating (inch) | Male PT 1″ |
| SOUND POWER LEVEL (OUTDOOR UNIT) | |
| Rated / low noise mode (dB(A)) | 61 / 60 |
| SOUND POWER LEVEL (INDOOR UNIT) | |
| Rated (dB(A)) | 44 |
| SOUND PRESSURE LEVEL AT 5M (OUTDOOR UNIT, CONVERT USING SWL) | |
| Rated / low noise mode (dB(A)) | 39 / 38 |
| SOUND PRESSURE LEVEL AT 1M (INDOOR UNIT, CONVERT USING SWL) | |
| Rated (dB(A)) | 36 |
| DIMENSIONS | |
| Outdoor unit (WхHхD), (mm) | 950 х 1,380 х 330 |
| Indoor unit (WхHхD), (mm) | 490 х 850 х 315 |
| WEIGHT | |
| Outdoor unit (empty), (kg) | 91,7 |
| Indoor unit (empty), (kg) | 30,5 |
| EXTERIOR | |
| Outdoor unit (color / RAL code) | Warm gray / RAL 7044 |
| Indoor unit (color / RAL code) | Noble white / RAL 9016 |